VCB Interrupter

VCB Interrupter (vacuum circuit breaker arc extinguishing chamber) is a key component for efficient breaking and closing of current in power systems. It uses a high vacuum environment to ensure that the arc is quickly extinguished when the contacts are separated, and has excellent breaking performance and high reliability. The product has excellent insulation performance, environmental protection characteristics and long service life, and is widely used in medium and high voltage power transmission and distribution systems, such as industrial power grids, substations and rail transit, to ensure the safe operation of power equipment.
Send Inquiry
Description

VCB Interrupter (vacuum circuit breaker arc extinguishing chamber) is a key component for efficient breaking and closing of current in power systems. It uses a high vacuum environment to ensure that the arc is quickly extinguished when the contacts are separated, and has excellent breaking performance and high reliability. The product has excellent insulation performance, environmental protection characteristics and long service life, and is widely used in medium and high voltage power transmission and distribution systems, such as industrial power grids, substations and rail transit, to ensure the safe operation of power equipment.

 

Features And Advantages Of Vcb Interrupter

 

1. High breaking capacity: vacuum medium quickly extinguishes arcs and adapts to high fault current environments.

2. Excellent insulation performance: vacuum environment provides extremely high dielectric strength to ensure system safety.

3. Environmentally friendly design: no harmful gas emissions, in line with green energy requirements.

4. Low maintenance cost: few mechanical parts, low wear and long service life.

5. Wide applicability: suitable for medium and high voltage power transmission and distribution scenarios, meeting various needs such as industry and substations.

 

Vcb Interrupter Precautions

 

1. Installation environment: ensure dryness, cleanliness, and no strong vibration and corrosive gas.

2. Operation specifications: follow the product manual to avoid overload or frequent switching.

3. Regular maintenance: check the vacuum degree, contact wear and mechanical component status to ensure stable performance.

4. Storage conditions: avoid high temperature, high humidity and strong magnetic field environment to prevent performance degradation.

5. Safety protection: insulation and protection measures must be taken during operation to ensure personnel safety.

Technical Parameters

 

MAIN TECHNICAL DATA    
Data Unit Value
Rated Frequency Hz 50
Rated Voltage kV 12
Rated Short-duration Withstand Voltage(1min) kV 48
Rated Lightning Impulse Withstand Voltage kV 85
Rated Current A 1600
Circuit Resistance at the Lowest Rated Contact Force μΩ ≤20
Rated Short-circuit Breaking Current kA 31.5
Rated Short-circuit Breaking Current Breaking Times Times 50
Rated Short-duration Withstand Current kA 31.5
Rated Duration of Short-circuit s 4
Rated Peak Withstand Current kA 80
Rated Short-circuit Making Current kA 80
Rated Operaing Sequence   O-0.3(0.5)s-CO-180s-CO
Contact Stroke mm 11±1
Contact Closing Force N 110±50
Force Required to hold contacts open at full stroke N 180±50
Average Opening Speed (first 75% stroke) m/s 1.4±0.2
Average Closing Speed (last 30% stroke) m/s 0.8±0.2
Rated Contact Force N 3100±200
Contact Force at the Touch Point N 2200±150
Contact Closing Bouncing Duration ms ≤2
Contact Opening and Closing Non-simultaneity ms ≤2
Contact Opening Rebound Amplitude mm ≤2
Storage Life Years 20
Mechanical Endurance Times 10000
Contact Erosion Limit mm 3

 

Hot Tags: vcb interrupter, China vcb interrupter manufacturers, suppliers, factory, vacuum interrupter for hospital facilities, vacuum interrupter for defense applications, vacuum interrupter for government buildings, vacuum interrupter for renewable energy systems, vacuum interrupter for wastewater treatment systems, vacuum interrupter for otolaryngological equipment