SVG Type Magnetic Control Fast Vacuum Circuit Breaker

SVG Type Magnetic Control Fast Vacuum Circuit Breaker
Product Introduction:
SVG-12/17.5-630/1250-25 Magnetic control fast circuit breaker SVG-12/17.5-630/1250-25 magnetron fast circuit breaker is an indoor medium voltage atmospheric pressure gas insulated ring network cabinet based on semi-hard magnetic material operating mechanism. The main equipment consists of SVG-12/17.5-630/1250-25 magnetron fast circuit breaker body and supporting SVG380D control terminal.
Send Inquiry
Description
Technical Parameters

 

Product Overview

 

Product introduction

SVG-12/17.5-630/1250-25 magnetron fast circuit breaker is an indoor medium voltage atmospheric pressure gas insulated ring network cabinet based on semi-hard magnetic material operating mechanism. The main equipment consists of SVG-12/17.5-630/1250-25 magnetron fast circuit breaker body and supporting SVG380D control terminal.

 

Product standard

GB 1984-2014 AC High Voltage Circuit BreakerJB 3855-2008 High Voltage AC Vacuum Circuit BreakerDL 403-2000 Technical Conditions for Ordering 12kV~40.5kV High Voltage Vacuum Circuit Breakers

 

Ambient condition

1.3.1 Altitude: Areas up to 2000 meters.1.3.2 Ambient temperature: Maximum temperature: +70℃, minimum temperature: -40℃ , daily average temperature not greater than: +30℃.1.3.3 Ambient humidity: Daily average relative humidity: less than or equal to 95%, monthly average relative humidity: less than or equal to 90%.

 

 

technical parameter (SVG Breaker Body)

 

Parameter name Value
Nominal
parameter
1 Rated voltage 12/17.5kV
2 Rated current 630A/1250A
3 Rated power frequency withstand voltage Ground 42kV, break 48kV
4 Rated impulse withstand voltage 75kV
5 Rated short circuit breaking current 25kA
6 Rated short circuit closing current 63kA
7 Rated short-time withstand current 25kA
  8 Rated cable charging breaking current 25kA
9 Rated overhead line charging breaking current 10kA
10 Rated short-term endurance time 4s
11 Rated frequency 50Hz
machinery electrical function 12 Operation cycle of split (no load, mechanical life) 50,000 times
13 Operation cycle of fusion and division at rated current 50,000 times
14 Operation cycle of fusion and division under rated short circuit current 100 times
15 The bounce time is not greater than 2ms
16 The time of opening shall not exceed 5ms
17 The time period is not greater than 2ms
18 Rated operating cycle O-0.3s-CO-15s-CO
19 The main circuit resistance is not greater than 30μΩ
weight 20 Three-phase weight 40Kg

 

Table 1: Technical parameters of circuit breaker body

 

Install (SVG Breaker Body)

 

Δ Note: All work in the installation and operation of circuit breakers should be carried out by personnel who have been specially trained and have a detailed understanding of the performance of the switchgear, and appropriate protection and preventive measures must be taken during the work.

 

Overall structure diagram of circuit breaker

 

Overall structure diagram of circuit breaker

 

 

Figure 1: Overall view

 

legend:

①Moving contact of circuit breaker;

②Static contacts of circuit breaker;

③Fix the main pole;

④Circuit breaker mechanism room;

⑤Grounded threads;

⑥Circuit breaker nameplate;

⑦Circuit breaker terminal;

⑧Manual operation of circuit breaker flat position;

 

Circuit breaker structure diagram

Lateral view:

product-1149-438

 

Figure 2: Right view                                                                                   Figure 3: Left view

 

Front view of circuit breaker:

product-1123-532

Figure 4: front view of the circuit breaker (emergency opening by manual insertion);       Figure 5: rear view of the circuit breaker

 

Reference diagram of the overall size of the circuit breaker:

product-1264-549

Figure 6: Overall size of circuit breaker

The circuit breaker has a phase spacing of 180, a total pole height of 278, a box length of 530, and a box width of 140, with the total height of the entire unit being 445 mm. The static contact copper busbar measures 6010 mm, and the moving contact soft copper busbar is 508 mm. The static contact copper busbar is fixed at a distance of 28 mm, with a fixing hole size of 2*Φ10 mm. The moving contact soft copper busbar has a fixing hole size of Φ13 mm, and the grounding nut hole is M10.

 

Circuit breaker fixed size diagram:

Front view fixed size diagram

Figure 7: Front view fixed size diagram

Rear view external size diagra

Figure 8: Rear view external size diagra


The circuit breaker is fixed by auxiliary clamping plates on both sides, and four M10-30 fastening screws are selected for each side.

 

Reference diagram of circuit breaker moving/static contact wiring dimensions:

product-339-389

Figure 9: front view of the size of the hard copper bars of the static contacts of the circuit breaker

product-542-455

 

 

Figure 10: top view of the size of the soft copper bars of the moving contacts of the circuit breaker


Figure ①shows the dimensions of the moving contact flexible copper busbar, which is typically configured with a 630A rating and features a thickness of 10mm and a width of 50mm. Special orders require specific instructions. Figure ②shows the dimensions of the stationary contact rigid copper busbar, which is generally 10mm thick and 60mm wide, meeting the basic requirements for a 1250A rating. The stationary contact copper busbar is fixed at a distance of 28mm, with two Φ10mm fixing holes. The moving contact flexible copper busbar uses a Φ13mm fixing hole. When fixing the copper busbar, it is important to consider the redundancy space for switch operations to ensure normal operation.

 

 

Reference diagram of the size of the reliable grounding point of the equipment:

product-854-603

Figure 11: Size of reliable connection point for circuit breaker

Note ⑤is the location map of the reliable grounding point of the equipment. It is generally recommended to use M10-30 specification screw for grounding bolt.

 

Packaging, transportation and storage

 

The outer box is a carton, and the inner protection is polystyrene foam. There are no special requirements for transportation.

 

Storage

 

(1) Should be stored in a dry, dust-free and well-ventilated place.

(2) When stored, the circuit breaker should be in the open state.

(3) Every time the storage time exceeds half a year, the drive module needs to be powered on once and connected to the circuit breaker for switching operation.

 

Maintenance and maintenance

 

During the life period, maintenance is free and no adjustment is required for the mechanical parts. Dust removal should be done during maintenance.

 

Packing List

 

order number name quantity unit
1 Circuit breaker body 1 short for Taizhou
2 control terminal 1 short for Taizhou
3 Product installation and use manual 1 stem or root of plants

Table 3: Packing list

Attachment: Equipment use vacuum arc extinguishing chamber parameter manual

 

MECHANICAL DATA of VACUUM SWITCH
No. Name of Parameter Unit Value
1 Contact Stroke mm 8±1
2 Average Opening Speed (first 75% stroke) m/s 1.1±0.2
3 Average Closing Speed (last 30% stroke) m/s 0.9±0.2
4 Rated Added External Contact Force N 1800+300
5 Contact Initial Pressure N 1300±200
6 Contact Closing Bouncing Duration ms ≤2
7 Contact Opening and Closing Non-simultaneity ms ≤-
8 Contact Opening Rebound Amplitude mm ≤2

 

MAIN TECHNICAL DATA
No. Name of Parameter Unit Value
1 Rated Voltage kV 17.5
2 Rated Current A 1250
3 Rated Frequency Hz 50/60
4 Rated Short-duration Withstand Voltage kV 48
5 Rated Lightning Impulse Withstand Voltage kV 85
6 Rated Short-circuit Breaking Current kA 25
7 Rated Peak Withstand Current kA 63
8 Rated Short-circuit Making Current kA 63
9 Rated Short-duration Withstand Current kA 25
10 Rated Duration of Short-circuit s 4
11 Rating current of single capacitor bank A 630
12 Rated back to back capacitor bank breaking current A 400
13 Rated Short-circuit Breaking Operations Opr 30
14 Mechanical Endurance Opr 30000
15 Contact Closing Force N 110±40
16 Force Required to hold contacts open at full stroke N 190±40
17 Circuit Resistance at the Lowest Rated Contact Force μΩ ≤15
18 Contact Erosion Limit mm 3
19 Internal Gas Pressure Pa ≤1.33x10⁻³
20 Mass of Moving Parts kg <0.6
21 Storage Life Years 20
22 Rated Operating Sequence O-0.3s-CO-180s-CO
**※**In transformer oil or equivalent insulating medium

 

product-451-699

TD-17.5/1250-25(X899)

Vacuum Interupter for Circuit-Breaker

 
Please contact with us to get the catalogue.

 

Hot Tags: svg type magnetic control fast vacuum circuit breaker, China svg type magnetic control fast vacuum circuit breaker manufacturers, suppliers, factory, vacuum interrupter for augmented reality systems, vacuum interrupter for grid connection, vacuum interrupter for hydro power, vacuum interrupter for irrigation systems, vacuum interrupter for libraries, vacuum interrupter for neurological equipment