24kV Pole Mounted LBS SF6 Circuit Breaker

Send Inquiry
Description
Description 24 kV
Nominal system voltage: kV 24
Maximum system voltage: kV 27
System Fault Rating: kA 20
Insulation class: 1.2 / 50 μs; Lightning impulse withstand voltage: kV 125
Insulation class: 1.2 / 50 μs; Lightning impulse withstand voltage: kV 145
Power frequency (1-minute withstand, damp conditions): kV 50
Steady-wave power supply frequency (1-minute withstand, damp conditions): kV 50
Creepage distance The maximum system voltage is 31 mm/kV
Neutral grounding configuration Effectively grounded

 

Number of phases Three-phase
Nominal normal current 1250A
Mechanical endurance M2 class
Electrical endurance E3 Level
Rated short-circuit performance: kA
Rated short-circuit withstand current (peak value) 50
Short-term withstand current (1 sec) 40
Nominal short-circuit current (peak value) 50
Insulation grade
Rated electrical impulse withstand voltage 125kV pk
Nominal short-time power-frequency withstand voltage test (wet condition, 1 minute) 50kV
Insulator creep distance 31Mm/KV

 

LBS design
Insulating medium SF6
Operating room The LBS should be equipped with self-
contained SF₆ compartments for each stage,
including the operating mechanism.
Suspend Secondary SF6
Operating mechanism The three poles should be operated simultaneously via the spring mechanism.
Instruments/Sensors
Current Transformer/Sensor Configure a CT for each stage to measure
the stage current and activate the protection
scheme.

 

Voltage Transformer/Sensor The VT/voltage sensor module for each phase is used to measure voltage; the
enabled protection schemes include overvoltage and undervoltage settings.
Accuracy Current: ±0.5%; Voltage: ±0. 1%
Measuring the open/closed/locked and trip states
Tripping mechanism Tripping shall be initiated in accordance with the protection scheme specified below.
Automatic Switching Solution At least four O–Co–Co–CO switching cycles; according to IEC 62271, the dead time can be selected independently.
Manual Lock/Unlock
The manual locking/unlocking function is implemented via a liver mechanism controlled by a ground operating lever; this mechanism operates at the locked position.

When setting up, all operations should be disabled and LBS should be enabled.
From the ground, the locked and unlocked positions should be clearly visible.
Protection Plan
Frequency Protection The device shall provide over-frequency and under-frequency protection within a range of ±5
Hz above or below the system frequency, with a step size of 0.1 Hz. The device shall also
incorporate an automatic closing function that enables re-engagement once the frequency
returns to normal after a tripping event caused by over-frequency or under-frequency conditions.
Voltage Protection The device shall provide overvoltage/undervoltage trip setpoints in increments of 1% of the nominal
system voltage, applicable for the ranges of 100%–150% (overvoltage) and 50%–100%
(undervoltage).
Overcurrent and ground fault operating characteristics According to IEC 60255, these include instantaneous inversion, standard inversion, non-standard inversion, and extreme inversion.
Overcurrent setpoint range 25%–150% of the rated current
The minimum resolution is 1 A.
Ground fault detection scope Ranging from 5% to 50% of the rated current, with a minimum resolution of 1 A.
Sensitivity setting range for ground faults The current transformer's rated current range is 0.5% to 8% of the rated current, with a minimum resolution of 0.5 A.
Protection Configuration Facilities for integrating protection configuration profiles shall be provided.
Cold Load Collection (CL-PU) The Cold Load Collection (CLPU) facility is designed to prevent control system tripping caused by
short-term current surges resulting from the loss of normal load diversity. This includes the cold
loading duration and user-defined parameters.
Surge suppression protection A device that utilizes the overcurrent protection time setting and surge suppression factor configured by the user.
High-current lockout When the continuous current condition exceeds the user-defined high current lockout threshold, the
LBS can directly perform an LBS lockout. Under these conditions, the LBS shall not re-close, and
it shall provide an indication and signal.
Dead zone setting range 0.5 to 120 seconds.
Reset time setting range 5 seconds to 180 seconds

 

term of service
1 Altitude (above sea level) 1800m
2 Maximum outdoor temperature 50℃
3 Minimum outdoor temperature -20 ° ℃
4 Maximum monthly primary operating temperature 35 °C
5 Annual average temperature 25 ° ℃
6 Maximum relative humidity Up to 96%
7 Isolarnic level 180 thunderstorm days per year
8 Maximum lightning strike frequency Twice per kilometer each year. Total: 32 times
9 Maximum wind velocity 100 km/h
10 Maximum solar radiation
Insulation layer on the floor plan
1035W/m2
11 Maximum soil temperature (at 1-meter depth) 30℃
12 Soil maximum temperature resistance 2℃ m/W
13 Maximum soil electrical resistance 2000 Qm
14 Seismic zones (Modified Mecalli scale) Zone 8
15 Seismic coefficient 0.15
16 Atmospheric Type Maritime
17 Air pollutant Sand, dust, salt

 

18

Pollute According to IEC 60815, the design pollut-
ion class shall be "Heavy" (Pollution Class II).

 

Technical Timeline
Technical Data Progress Schedule for the Load Disconnection Switch Main Unit (Circuit Breaker)
S/N Function Description Bidders' Documentation
1 Type Column-type outdoor SF₆
circuit breaker
 
2 International standard IEC 62271-103 KEMA  
3 Country of origin Specification  
4 Manufacturer Specification  
5 Fabrication Specification  
6 Rated frequency (Hz) 50  
7 Rated current (A) 630  
8 Rated voltage (kV) 24  
9 Rated voltage (KV) 27  
10 System fault level (kA) 20  
11 Continuing current rating (A) 630  
12 Short-circuit breaking capacity (kA) 20  
13 Peak short-circuit fault current (kA) 50  
14 Short-circuit rated duration (seconds) 4  
15 Symmetric (rms)(kA) 20  
16 Asymmetric (RMS) (kA) 20  
17 Close/Open Time (seconds) <0.7  
18 Mechanical Operation (Verification) (No.) 10000  
19 Electrical Durability (Guaranteed) 10000  
20 Tank Materials Stainless steel  
21 Thickness (mm) ≥3  
22 Pigment Gray RAL 7035  
23 Tank welding types TIG weld  
24 Tank bursting pressure (kgf/cm²) 4–6  
25 Enclosure IP Rating (Minimum) IP67  
26 Reference Manufacturing Standards IEC 62271-103  
27 Material/Color Specification  
28 Maximum system voltage creepage distance (mm) ≥31 kV  
29 Power-frequency withstand voltage (1 minute) (kV) 50  
30 Lightning impulse withstand voltage (kV) 125  
31 Terminal Type NEMA  
32 Insulation and circuit breaker compartment SF6  
33 SF₆ Valve Room Lifelong sealing  
34 Arc-extinguishing medium SF6  
35 Insulating medium SF6  
36 According to IEC Standard 62271: Sealed Pressure Systems Mandatory  
37 Using the mechanical operating device, the lever can be easily operated from the ground. Yes  
38 Manual control comprises a tubular linkage rod made of hot-dip
galvanized steel; this tubular linkage rod is connected to an
independent controller and is equipped with a handle for manual
operation from the bottom ofthe rod. (Yes/No)
Yes  
39 This connection includes a pipe that can be easily adjusted to any rod height. Yes  
40 All steel components of the operating mechanism shall be hot-dip galvanized. Yes  
41 Set the "Open" position and lock the switch in the open position. (Yes/No) Yes  
42 The "Off" position: The switch is locked in the off position. (Yes/No) Yes  
43 Manual operating force (Newtons) <200  
44 Is the lever separated from the lever arm and operating handle (Yes/No)? Yes  
45 Whether the LBS manufacturer manufactures the mechanism (Yes/No) Yes  
46 Phase difference (mm) 380  
47 Ground displacement (mm) 330  
48 Arrester rated voltage (KV) 36  
49 Radio frequency interference voltage (uV) Specification  
Note: Please fill out a timetable for each type of circuit breaker.

 

2.1 Input and output phase current input
Quantity: 3
Rated Current:5A,Measurement Range:20×
In; Instrumentation Accuracy: ≥0.1 ×
In ±1%In;Frequency of Measurement: 50
times per hour
Heat-resistant:
Continuous 2*In
10 The second 10*In
1 Second 40*In
Load @In ≤ 0.2 VA (5A phase element)
Sensitive current input
Quantity 1
Rated current: 5A
Measurement range: 2 × rated current; Inst-
rumentation accuracy: ≥ 0.1 × rated current; ±
1% of rated current; Frequency: 50/60 Hz
Heat resistance: Continuous 2*In
10 Second 10*In
1 Second 40*In
Load @In ≤ 0.02 VA (1-ampere grounded component)
Voltage input
Quantity:1 PT voltage
Nominal value: 40.120 Vrms
Operating ran.g.e.: 0–200 Vrms; Inst-
rumentation accuracy: ≥0.8×Vn ±1%
Vn;Load@110 V, 0.06 VA
Withstand voltage: 240 Vrms
Auxiliary supply
DC voltage: 220V
Voltage range: 165–365 V
AC voltage: 220 VAC, 50 Hz
Operating range: 165–265 Vrms, AC 50/
60 Hz, ±5%;Power consumption ≤ 10 W
Binary input
No.7
Operating voltage: 24 V DC; maximum operating DC current: 2 mA
Binary output
Number 2
Operating voltage: 220V DC
Operating mode: Users can select between self-reset or manual reset/electrical reset, or pulse-based operation; the operating time is timed from the moment power is applied (<20 ms input).
2.2 Unit Design
Indicator light 16,4-line character display
10, LED user interface 11, navigation keys
Weight: 18 kg
2.3 serial interface
Communication ports: RS485, RS232, RJ45, USB, HDMI
Protocols: IEC 60870-5- 101; IEC 60870-5- 104; DNP3.0, MODBUS RTU, FTU
2.4 data storage
Event count: 150, 100
2.5 mechanical test
Vibration (sine wave) - IEC 60255-21- 1 Class I
Type: Vibration Compression strength 0-grade, 1.5g, 1.0g Change ≤
5% ≤5%
Impact and Collision – IEC 60255-21-2 Class 1
Type Rank Difference
Impulse response 0.5gn,11ms ≤5%
Resistance to impact 15gn,11ms ≤5%
Bump test 10gn,16ms ≤5%
Impact and Collision – IEC 60255-21-3 Class I
X-Plane-3 model, rated voltage level. The displacement below the crossover frequency (8–9 Hz) is 1 g
<sub>n</sub>.Seismic response and ≤5%Y-plane displacement: 1.5 mm,below the crossover frequency
(8-9 Hz)≥ .5 g<sub>n</sub>
Mechanical Classification
Durability> 10⁶ cycles
2.6 Electrical Testing
Insulation – IEC 60255-5
Type Level
Between any terminal and ground, a 2.0 kV AC RMS voltage shall be applied for 1
minute between the normally open contacts; additionally, an AC voltage of 2.0 kV
RMS shall be applied for 1 minute.
High-frequency interference - IEC 60255-22- 1 Class III
Type
Standard (Vertical) Mode Series (Horizontal) Mode
Rank
2.5 kV
1.0 kV
Change
≤5%
≤5%
High-frequency interference - IEC 60255-22-2 Class IV
Type Rank Diffe-
rence
Contact discharge 8.0 kV ≤5%
Fast Transient-IEC 60255-22-4 Class A (2002)
Type Rank Diffe-
rence
5/50 ns, 2.5 kHz repetition rate 4 kV ≤5%
Anti-interference – IEC 60255-22-5
Type Rank Difference
Analog input:
Earth ground
connection
4.0 kV ≤10%
Case Study: Aux Power & I/O: Line to Earth 2.0 kV ≤10%
RS485 communication port: Line-to-ground 1.0 kV No data loss
Analog Inp-
ut: Line-by-
Line
1.0 kV ≤10%
Case Study: Aux Power & I/O: Line-to-Line 1.0 kV* ≤10%